UEI C157 EAGLE 3X eXtended Life Combustion & System Analyzer with Oil Burner Kit
The newly redesigned Eagle 3X Combustion System Analyzer eliminates the number
one hassle for combustion contractors; the annual replacement and calibration of
the O2 sensor. By replacing the electro chemical O2 sensor
with the EOS Technology™ CO2 sensor, the EAGLE 3X now takes direct CO2
measurements and calculates the O2 level. This lowers the cost of
ownership by doing away with the annual replacements of the O2 sensor
and reducing calibration drifting typically found with standard electro-chemical
sensors. The EOS Technology sensor is warranted for 5 years and has an unmatched
industry-leading life expectancy of 10 years! Features:
- Measures: Differential flue temperature, Carbon Dioxide CO2,
flue & ambient carbon monoxide CO, Nitric Oxide NOx & Hi-Res Differential Pressure
- Calculates: Oxygen O2, gross/net efficiency, excess air, & CO
air free
- High level CO alarm
- CO data logger
- Heat exchanger test
- Built-in Worklight
- Large 4 line backlit LCD display
- 179 memory positions
- User customizable parameters view
- Individual report printouts
- Unique DMM style rotary selector
- Protective boot with integral magnet
- Real time clock with date & time stamp
- CO readings to 1ppm
- Infrared printer port
- Battery level indicator
- Field replaceable sensors (USA only)
- Gas Zero (Fresh Air Zero) - Is a reset procedure to maintain accurate
readings
from the EOS sensor. This procedure compensates for any change in ambient conditions that may impact the readings.
Specifications:
|
Flue Temp Range:
|
20° to 2400°F (-29° to 1315°C) |
|
Inlet Temp Range:
|
20° to 2400°F (-29° to 1315°C) |
|
Inlet Temp Range (Ambient):
|
32° to 112°F (0° to 50°C) |
|
Net Temp (ΔT):**
|
20° to 2400°F (-29° to 1315°C) |
|
Resolution:
|
0.1°F/°C |
|
Flue (T1, Inlet T2, & Net ΔT)
Accuracy:
|
±[0.3% reading + 3.6°F (2°C)] |
|
Inlet Temp Ambient Accuracy:
|
±[0.3% reading + 1.8°F (1°C)] |
|
Oxygen O2:**
|
0 to 21% |
|
O2 Resolution/Accuracy:
|
0.1% / ±0.3% |
|
Carbon Monoxide CO:*
|
0 to 2000ppm (4000 max 15 min) |
|
CO Resolution/Accuracy:
|
1ppm / ±10ppm <100ppm ±5% reading |
|
Carbon Dioxide CO2:*
|
0 to 20% |
|
CO2 Resolution/Accuracy:
|
1.0% / 0.2% reading |
|
Efficiency**:
|
0 to 99.9% |
|
Efficiency Resolution/Accuracy:
|
0.1% / ±1.0% reading |
|
Excess Air**:
|
0 to 250% |
|
Excess Air Resolution/Accuracy:
|
0.1% / ±0.2% reading |
|
CO/CO2:**
|
0 to 0.999% |
|
CO/CO2 Resolution/Accuracy:
|
0.0001% / ±5% reading |
|
Nitric Oxide NOx:
|
0 to 100ppm |
|
Nitric Oxide Resolution / Accuracy
|
±2ppm <30ppm / ± 5ppm >30ppm |
|
Pressure (Differential)
|
Accuracy |
|
±0.08" wc (±0.2mBar)
|
0.001mBar / ±0.005mBar ±0.002"wc |
|
±0.4" wc (±1mBar)
|
0.001mBar / ±0.03mBar ±0.01"wc |
|
±32" wc (±80mBar)
|
±3% reading |
|
Pressure resolution: |
0.001"wc < 9.999"wc
0.01"wc >10.00"wc
0.001mBar <24.999mBar
0.01mBar >25 mBar |
* Measured at STP (standard temperature and pressure) ** Calculated value
- Weight: 2.2lbs. with boot
- Handset: 7.9" x 1.8" x 3.5"
- Probe: 11.8" x 0.25" x 9.4" stainless steel shaft, type K thermocouple
(9' hose)
- Operating temperature range: 32° to 104°F (0° to 40°C)
- Operating humidity range: 10 to 90% RH
non-condensing
- Power: 4 AA cells / 12 hour life typical with Alkaline AA cells
- Pre-Programmed Fuels: Natural Gas, Propane, Butane, LPG, Light and Heavy Oil, Bio-Fuel,
Wood
Includes:
- C157 Analyzer
-
Depth stop cone
-
Flue Probe
- 9' Neoprene hose with incorporated "k"
type thermocouple end
- Ruggedized boot with integral magnet
- (2) Particle filters 17631
- Hard shell carrying case AC509
- Quick & Users start manual
- Infrared Thermal Printer KMIRP2
- (2) rolls of thermal printer paper
16646
-
(2)
K-Type Temperature Probes
- (2) Static Pressure Hoses
- True Draft Probe
- Gas Tap and Hose
- (4) AA alkaline batteries
- Smoke Pump Tester
- Smoke Test Paper & Chart
-
5 year limited manufacturers warranty (including sensor)
Download Users manual
(PDF format)
Download QUICK START manual (PDF format)