Inspector Tools, Smoke Testing, Test-Kits and Safety Products
Meters, Test Kits, Inspection Equipment & Tools!
[ 0 Items | $0.00 | 0 lbs ]
Search Catalog:
Categories
Anemometers-Air Flow

Borescope Videoscope

Carbon Monoxide (CO)

Circuit & Power Testers

EMF / Microwave Meters

Fire and Smoke Safety

Gas and Leak Detectors

Hygiene / ATP Testing

Hygrometers / Humidity

Inspection Kits / Forms

Light, LUX, UV Meters

Lights / Flashlights

Magnifiers / Binoculars

Manometers / Pressure

Measuring Instruments

Meter Accessories

Moisture Detectors

Promotional Items

Radon Gas Testing
|_NJ Radon Test Kits

Radon Mitigation

Refractometers - BRIX

Security and Safety

Smoke Trace Emitters

Soil & Grain Meters

Sound Level Meters

Specialty Instruments

Thermometers

Timers and Clocks

Tools and Hardware

Water & Flood Alarms

Water Testing
Customer Service
Customer Service
About Us
Shipping Policy
Return Policy
Privacy Notice
Conditions of Use
Contact Us

Radon Gas Air Test Vial Short Term (rn-LS) Lab Fee Included

Model #: rn-LS
Regular Price: $19.99
$10.75

Print Friendly View
Add Qty to Cart:  

Radon Gas Air Test Vial Short Term (rn-LS) Lab Fee Included
Click to Enlarge

Reviews
Quantity Discounts
1-3 4-1112-4950-99100+
$10.75$10.48$10.21$9.68$9.14
First Product Previous Product Product 4 of 21 Next Product Last Product
Category Radon Gas Testing

LAB FEES INCLUDED. Do-it-yourself kit will include: (1) Short Term Radon in air (48-96 hour exposure period) Liquid Scintillation radon test vial, pre-addressed Priority Mailer (1 per order) & easy to follow instructions. Extremely accurate & easy to use! Quick & reliable lab results are included in price. EPA recommends using 2 canisters per 1200 square foot dwelling. Lab results are available online within 24-36 hours of receiving them back in our lab.click here for results.

OUR LABS ARE EPA CERTIFIED Click here for NJ testing

Download Instruction Sheet / Information Form

For short-term radon measurements with exposure times between 48 hours and 96 hours, we utilize the liquid scintillation (LS) type of patented pharmaceutical-grade charcoal-silica adsorption material. Near 100% counting efficiencies allow for a monitor that is lighter in weight (0.4 ounce) and easier to handle than traditional charcoal canisters. High efficiency counting also means that fewer samples are lost due to excessive decay time.

Each detector is given a unique bar-coded identification number. A measurement with the LS device in initiated by removing the cap to allow radon-laden air to diffuse into the charcoal packet where the radon is adsorbed. A polyethylene foam plug ensures passive diffusion, preventing distortions caused by drafts and air currents. At the end of the exposure (two days), the device is resealed securely and returned to our lab for analysis.

In the laboratory, the exposed detectors are prepared for analysis by radon desorption techniques. A major fraction of the radon adsorbed on the carbon is transferred into a vial of liquid scintillation fluid. The vials of counting fluid are then loaded into an automated liquid scintillation counter. The total beta activity is then counted for a pre-set time or until the standard deviation of the counts is at 2.5%.

The total beta count, along with the customer supplied exposure data, is used to calculate the radon concentration. The typical uncertainty (standard deviation) of an LS result is 10% and the minimum reported concentration is 0.5 pCi/l.

Learn more about Radon (New window will open and take you to our Radon Information site)

Click here for NJ testing

Search Category: Home & Garden > Fire & Gas Safety
First Product Previous Product Product 4 of 21 Next Product Last Product
Category Radon Gas Testing
Customers who bought this product also purchased these items:
Corentium Digital Radon Gas Detector (COR1) Battery Operated
Corentium Digital Radon Gas Detector (COR1) Battery Operated
Offset Coupling for RadonAway SF180 Radon Fan (13165) 4" to 3"
Offset Coupling for RadonAway SF180 Radon Fan (13165) 4" to 3"
Roof Vent Cap 3 Inch PVC White (76001) Schedule 40
Roof Vent Cap 3 Inch PVC White (76001) Schedule 40
Exterior RadonAway Fan 149 CFM 53-71 watts (SF180) 4 Inch
Exterior RadonAway Fan 149 CFM 53-71 watts (SF180) 4 Inch
Welcome
Login:
eMail Address:
Password:
Forgotten Password?
Click Here
First Time Visitor?
Join Free
Manufacturer Info
-Other products
Notifications more
Notify me of updates to Radon Gas Air Test Vial Short Term (rn-LS) Lab Fee Included
Dashboard
Radon Results Lookup
Cable Length Calculator
Carbon Monoxide Gas
CO Detector Badge
Conversion Calculators
Radon Gas Facts
Smoke Calculator
INSPECT USA BLOG
Quick Find

Search Catalog:
Advanced Search
What's New? more
SDI PowerChecker (PC01) Pulse Load Multiple Battery Tester
SDI PowerChecker (PC01) Pulse Load Multiple Battery Tester
$149.00
  Your IP Address is: 54.144.68.27
Copyright Inspect USA® 2015. All rights reserved. No part of this website may be reproduced without our express consent.

InspectUSA.com - Distributors of TestKits, Inspection Gear & Safety Equipment.
eMail with suggestions, product inquiries or comments. Thank you.