How does this radon gas detection process work?

Pro Series 3 Radon Gas Detector

 When the Po-219 decays by alpha emission, 50% of the alphas will be emitted into the detector junction where it forms a pulse of charge and is counted. The other 50% go undetected. In either case, the Po-218 decay product, Pb-214, will stay attached to the detector. The Pb-214 decays by beta emission to Bi-214. The beta is an electron with varying amounts of energy, depending on how the “beta decay” process shared its energy with a neutrino. But this is not important since the beta has a much lower LET (Linear Energy Transfer) than an alpha. This is a technical way of saying that the beta does not ionize the detector junction nearly as much as the alpha. The radon monitor has a threshold for the alpha energy to be counted; the beta is below this threshold.

So, the Pb-214 decays to Bi-214 by beta decay (~27 minutes) and the Bi-214 decays to Po-214 by beta (~20 minutes), putting the process back to a Polonium isotope. Now the Po-214 decays by alpha emission, 50% of which are detected just like the Po-218. This goes quickly, Po-214 half life is ~0.00016 seconds. At this point, we have counted about one alpha for every Rn-222 atom that diffused into the chamber, assuming that they all stay in the chamber. (This makes no difference if they diffuse out before decaying because others will diffuse in, establishing equilibrium.)

The Po-214 alpha decay forms a Pb-210 isotope. This is also a beta emitter, but its half life is ~22 years. However, it will accumulate on the detector and will be the source of background counting due to exposure to Rn-222. The more that accumulates, the higher the decay rate (disintegrations per unit time) will become. WhenPb-210 decays by beta, it forms Bi-210, which also decays by beta with a half life of 5 days, much faster that the Pb-210. From the Bi-210 decay we get Po-210, sounds familiar. The Po-210 will decay by alpha with a half life of about 138 days, and 50% of these decays will be counted which contributes to the background of the radon monitor. Since the 22 years is such a long time, this is not a serious problem, unless deployment of the monitor changes from a high concentration (for a long time) to a low concentration. As a rule of thumb, for every year a monitor sees an average concentration “C”, then the background will be about 1% of that average concentration. For example, if a radon monitor was deployed in a building for 5 years with an average concentration of 20 pCi/l, then the background counting rate would contribute about 1 pCi/l. (5*20*1% = 1)


The Pro Series 3 electronic radon gas monitor & alarm meets EPA Performance Criteria of the CR protocol.

Our electronic radon gas detector/monitor is a proven performer being in service since 1996. Used by inspectors, consultants and homeowners to monitor the radon gas levels in schools, offices and residences. It is a solid state continuous radon monitor which utilizes patented technology. At the heart of the device is a measurement circuit and pulse processing software which records alpha events on a photovoltaic sensor. Radon daughters create a spark when they come in contact with the potential across the collection dome and the photovoltaic sensor counts these pulses. The software equates pulse volume into pCi/L (Pico Curies per Liter) and then displays the information on the LED display.