Pro Series 2 has been upgraded to Pro Series 4.
Radon Gas Detector
The Pro Series II Radon Gas Detector allows the homeowner to
monitor the radon levels in their home by displaying short-term and long-term
averages.
• Numeric LED display range of 0 to 999 shows the level of
radon gas in pCi/L on a short-term or long-term basis.
• Short-term
readings display the average radon levels over the past 7 days.
•
Long-term readings display the average radon levels since powered-up or last
reset with a maximum reading time of 5 years.
• Audible alarm sounds if
the long-term average reaches 4 pCi/L or greater.
• Samples air
continuously with the display updated every hour.
• A self-test is conducted every 24 hours with an error code displayed if
there is a failure.
• 10' power cord allows user to locate detector away
from walls, windows and doors.
1 Year warranty.
Menu button
controls 4 functions.
1. Allows the user to switch between the short-term
and long-term display, which is indicated by a green LED illuminated next to the
S (short-term) or L (long-term).
2. Allows the user to conduct a manual
test of the detector.
3. Allows the user to mute or reactivate the
audible alarm if the detector is in an alarm state.
4. Allows the user to
clear and reset the memory of the detector to begin new readings.
Specifications
- Power Source Input: 120v AC / 60Hz at 9 Watts
- Power Source Output: 18v DC / 200mA
- Sensor: Ionization
Chamber
- Sensor Voltage: 250VDC
- Full Scale Reading:
999 pCi/L
- Rounding Less than whole numbers round down (3.9 = 3
displayed)
- Operating Environment: 0°C (32°F) to 70°C (158°F)
- Storage Environment: -20°C (-4°F) to 85°C (185°F)
- Audible Alarm: 85dB at 10cm.
- Beeps every hour if long-term readings are
4 pCi/L or greater. May be muted by the user.
- Averaging Frequency:
Levels will be updated on the display every hour.
Short-Term:
Average over the past 7 days.
Long- Term: Average from the time of
last reset. Maximum sampling time of 5 years. The detector will automatically
reset after 5 years of accumulated data.
- Accuracy: +/- 20% pCi/L
- Dimensions: 4.7" x 3.1" x 2.1".
Location of the Detector
The detector should be placed in the lowest living area of the home in a
location where it will not be disturbed. The audible alarm should be able to be
heard from areas frequented on a daily basis. Location of the detector should be
at least 3 feet from windows, doors, or any other potential openings in the
exterior walls; should be at least 1 foot from the exterior wall, and at least
20 inches from the floor. No other object should be placed within 4 inches of
the detector.
Areas to Avoid
• Near drafts caused by heating / AC
ventilation, vents, doors, fans and/or windows.
• Near excessive heat,
such as fireplaces & direct sunlight, and areas of high humidity.
• Near
televisions, computers, radios, or other electrical equipment.
• Near
curtains, furniture, or other items that may inhibit airflow through the
ventilation slots.
• In general, try to avoid locating in kitchens,
laundry rooms, closets, or bathrooms.
Installation
Your Radon
Detector is designed to plug into a standard 120-volt household outlet using the
attached power cord. Do not plug the detector into a wall outlet controlled by a
light switch.
The detector may be placed face-up on a tabletop, counter
top, or any flat surface where the ventilation slots will not be blocked. The
detector must be kept dust free. A proper airflow must be maintained through the
detector to obtain an air sampling representative of the local environment.
WARNING: Risk of severe electrical shock. There are no user serviceable parts
inside detector. Do not remove the back cover. Removal of back cover will void
any warranty.
Display Features
The numeric LED display shows the
level of radon gas in pCi/L. The numeric display is shown in whole numbers, no
decimals are used. Less than whole number readings are rounded down on the
numeric display (3.9 = 3 on the display). The display range is 0 to 999.
The Pro Series ll Radon Detector display is designed to notify the user of the
level of radon gas on either a short or long-term basis. The display updates
every hour if there is a change in the level of radon gas.
Short-Term
Display
The display for the short-term reading is an average of the
levels of radon gas over the past seven days. The short-term reading allows the
user to monitor short-term fluctuations in the home and provide a better feel
for problems relating to seasonal and weather related variations in the radon
levels. A green LED next to the letter "S" indicates this reading.
Long-Term Display
The display for the long-term reading is an average of
the levels of radon gas for the length of time that the detector has been
powered up or last reset. This reading relates to the average radon level that
you would be exposed to if you were in the continual presence of the Safety
Siren Pro Series II Radon Detector. A green LED next to the letter "L" indicates
this reading. The alarm feature of this detector is based on the long-term
reading. When the reading on the long-term reaches a level of 4 or greater an
audible alarm will sound.
Start-Up
Upon initial power-up, the
display will momentarily show an internal code including letters and numbers.
This code is used to determine if the detector is calibrated for use within the
USA or Europe. The detector will conduct a self-test and the audible alarm will
sound four chirps. The display will then read "-". The two dashes will remain
until sufficient samples have been taken to create an accurate reading. For the
short-term and long-term readings, samples need to be taken for 2 days (48
hours) before an accurate reading can be displayed.
Audible Alarm
If the long-term reading reaches a level of 4 or greater, an audible alarm
will sound. This is the level set by the EPA as the threshold at which action
should begin to correct the radon problem within the home. When the detector
goes into an alarm state, the buzzer will sound 4 short chirps. This sound will
be repeated every hour until the level on the long-term reading drops below 4 or
until the user mutes the alarm. Instructions for this function can be found
under Menu Button Operation.
Menu Button Operation
The menu button
controls 4 different functions for the radon detector. These functions are
controlled by the length of time that the button is pushed in.
1.
Long-Term / Short-Term
This function is used to change the display
between the short-term and long-term readings. Press the menu button in for one
second. The display will change the instant the menu button is released with the
LED indicator light lit next to the "S" or "L" to indicate which reading is now
being viewed. If the menu button is held in for longer than 3 seconds, the
display will not change.
2. Test
This function is used to test the
audible alarm. Press and hold the menu button in for 3 seconds. The alarm will
sound 4 chirps as if it is in an alarm condition. Release the menu button once
the alarm begins to sound.
3. Alarm Mute On/Off
This function
allows the user to silence the audible alarm. While in an alarm condition, press
and hold the menu button for 15 seconds. As you pass through the test phase as
indicated above, the alarm will sound 4 chirps. The display will read "Aoff".
Release the menu button as soon as "Aoff"is displayed. When the menu button is
released, the display will return to normal condition. If the long-term reading
returns to a safe level, the audible alarm will be reset to the on position. If
desired the alarm can be reactivated by repeating the same process. When
reactivating the alarm, the display will read "Aon".
Please note: This
function is only active when the detector is in an alarm condition with a
long-term reading of 4 or greater.
4. Reset/Clear Memory
This
function allows the user to clear and reset the memory for the short and long-
term readings. This should be done anytime the detector is moved to a different
location. Press and hold the menu button for 20 seconds. The display will read
"CL". When the menu button is released, the "CL" will flicker until the memory
has been completely cleared. Once the memory has been cleared, the display will
read "--" for 48 hours until enough samples have been taken to provide an
accurate reading. Please note: While using this function, the detector will pass
through the test and alarm functions as described above.
A brief
description of the Menu Button Functions can be found on the back of the
detector.
Error Messages
Every 24 hours, the detector will do a
self-test. If there is a failure in this self-test an error message will appear
in the display window.
Err3 Noise Error
This error is normally
from electrical noise interference. This error can be caused by computers,
televisions, fluorescent lights or other electrical items. The detector needs to
be moved to a different location away from the item causing the interference.
Err4 Sensor Error
This error occurs if the sensor fails the
self-test. If this error code appears, the detector needs to be replaced. Please
call our customer service department at 800-748-0298 for instructions on how to
have your detector replaced.
WARNING: Risk of Electrical Shock! Do not
remove the back cover. Sensor requires 250VDC and may cause severe electrical
shock. Removal of the back cover will void your warranty.
Note: To prolong the
life of the sensor and to ensure proper readings, vacuum the ventilation slots
on the detector, using the upholstery attachment on your vacuum every 3 months.
Facts and Concerns Regarding Radon Gas
Radon is a radioactive gas
that is colorless, odorless, and tasteless and is impossible to detect without
the use of sensitive test equipment. Radon is a naturally occurring gas produced
by the breakdown of uranium in soil, rock, and water. When allowed to accumulate
to high levels, it can be hazardous to long-term health. The Surgeon General has
warned that radon is the second leading cause of lung cancer in the United
States. Only cigarette smoking causes more lung cancer deaths. The EPA presently
suggests that corrective action be taken to reduce the radon levels in your home
if measured over the long term at 4 pCi/L or greater. For more information
regarding radon gas, please visit our web site.