Lutron Pitot Tube Anemometer and Differential Manometer (PAM-9212SD) with Data Logging Capabilities.

SD Card real time data recorder PITOT TUBE Anemometer & Manometer

  • Dual & differential input, 100 mbar max. range.
  • Air Velocity : 1 to 100.0 m/s.
  • Applications include: Industrial, laboratory, heating, ventilation, medical hospital, used for air or not corrosive and not ionized gas & liquid.
  • Sensor is built inside the housing.
  • Single plugs for pipe connection.
  • 12 kind display units ( mbar, Kg/cm2, mm Hg, meter H2O Atmosphere, psi, inch Hg, inch H2O, hpa, kpa, m/s, fpm ) select by push button on the front panel.
  • Auto shut off saves battery life.
  • Zero button on the front panel, easy to offset the zero value.
  • Microprocessor circuit assures maximum possible accuracy, provides special functions and features.
  • Super large LCD display.
  • Real time data logger, save the data into the SD memory card and can be downloaded to Excel.
  • SD card capacity : 1 GB to 16 GB.
  • LCD with green light backlight, easy reading.
  • It can default auto power off or manual power off.
  • Data hold, record max. and min. reading.
  • Power by UM3/AA (1.5 V) x 6 batteries or DC 9V adapter.
  • RS232/USB PC COMPUTER interface.
Circuit Custom single-chip microprocessor LSI circuit.
Display LCD size : 51 mm x 37 mm
LCD with green backlight ( ON/OFF ).
Display units Air vilocity : m/s, km/h, FPM, mph, knots
Air pressure: psi, inch Hg, inch H2O, h PA, kPA mbar, Kg/cm2, mm Hg, meter H2O, Atmosphere.
Measurement Function Air vilocity & Dual differential input, data hold,zero/relative, memory.
Zero adjust Push button on the front panel.
Sensor Sensor is built inside the housing.
Piezoelectric sensor.
Used for dry, non-corrosive and non-ionic air and gas only.
Not for use of Liquids.
Datalogger Sampling Time Setting range Auto 1 sec to 8 Hours 59 Minute 59 sec.
@ Sampling time can set to 1 second,but memory data may loss.
Manual Push the data logger button once will save data one time.
@ Set the sampling time to 0 second.
@ Manual mode, can also select the 1 to 99 position ( Location ) number.
Data error no. 0.1 % no. of total saved data typically.
Memory Card SD memory card. 1 GB to 16 GB.
Advanced settings
  • Set clock time (Year/Month/Date,Hour/Minute/ Second )
  • Set sampling time
  • Auto power OFF management
  • Set beep Sound ON/OFF
  • Decimal point of SD card setting
  • SD memory card Format
  • Air density setting
  • Data Hold Freezes the display reading.
    Memory Recall Maximum & Minimum value.
    Sampling Time of Display Approx. 1 second.
    Data Output RS 232/USB PC computer interface.
    Connect the optional RS232 cable UPCB-02 will get the RS232 plug.
    Connect the optional USB cable USB-01 will get the USB plug.
    Operating Temperature Meter 32° F to 122° F (0° to 50° C)
    Operating Humidity Less than 85% R.H.
    Power Supply Alkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.
    DC 9V adapter input. ( AC/DC power adapter is optional ).
    Power Current Normal operation ( w/o SD card save data and LCD Backlight is OFF) :
    Approx. DC 7 mA.
    When SD card save the data and LCD Backlight is OFF) : Approx. DC 25 mA.
    If LCD backlight on, the power consumption will increase approx. 10 mA.
    Weight 265 g / 0.59 LB.
    Dimension Meter 190 x 68 x 45 mm (7.5 x 2.7x 1.8 inch)

    Anemometer Specifications:

    Measurement Range Resolution Accuracy
    m/s 4.1 to 100.0 m/s 0.1 m/s ±( 3% + a ) reading or
    ±( 1% + a ) full scale
    Air density :1.200
    Km/h 14.7 to 360.0 km/h 0.1 Km/h
    Mile/h ( mph ) 9.1 to 223.7 mph 0.1 mph
    Knot 7.9 to 194.3 knot 0.1 Knot
    Ft/min 81-19685 ft/min 1 Ft/min
    @ a = 0.1 m/s, 0.3 km/h, 0.2 mile/h, 0.2 knot, 20 ft/min
    Note:
    • m/s - meters per second
    • km/h - kilometers per hour
    • ft/min - feet per minute
    • knot - nautical miles per hour mile/h miles per hour (international knot)

    Manometer Specifications:

    Unit Max. Range Resolution
    mbar 200.0 mbar 1 mbar
    psi 2.900 psi 0.1 psi
    Kg/cm2 0.204 Kg/cm2 0.001 Kg/cm2
    mm Hg 150.0 mm Hg 1 mm Hg
    Inch Hg 5.905 inch of Hg 0.01 inch Hg
    meter H2O 2.040 meter H2O 0.01 meter H2O
    h PA 200.0 h PA 1 h PA
    k PA 20.00 k PA 0.01 k PA
    inch H2O 80.20 inch H2O 0.05 inch H2O
    Atmosphere 0.197 Atmosphere .001 Atmosphere

    Supplied with:

    • Instruction manual
    • 160-18 Stainless steel Pitot tube, 5/16" diameter. 18-5/8" insertion length.
    • (2) quick coplers.
    • (2) 18" lengths of soft silicone tubing.

    Optional:

    • 16 gB SD Card SD-16gB.
    • Lutron Data Acquisition Software for Windows SW-U801-WIN.
    • Lutron USB Data Acquisition Cable with Driver USB-01.
    • RS-232 cable UPCB-02
    • Type K or Type J thermocouple probe Link.
    • USB to 9v DC power cable USBP-59.
    • 110v AC to 9v DC adapter AP-9V110.

    Search Category: Hardware > Tools > Measuring Tools & Sensors > Anemometers

    Product 18 of 18
    0 items
    Manufacturers
    Manufacturer Info
    Lutron