Arsenic Quick was designed to give the user accurate results without sacrificing cost and time. Designed using cutting-edge chemistry, Arsenic Quick reports results in only 12 minutes. Additionally, there are no dangerous chemicals needed to run this kit. With only one simple test procedure (using 3 reagents), Arsenic Quick is a must for any lab, water testing professional, or service technician who values accurate, rapid results without sacrificing cost.

  • Sensitivity: 0, 5, 10, 20, 50, 100, 200, >500 ppb (μg/L)
  • Total test time: 12 minutes

Inorganic Arsenic compounds in the water sample are converted to Arsine (AsH3) gas by the reaction of Zinc Dust and Tartaric Acid. Ferrous and Nickel salts have been added to accelerate this reaction. The Arsine converts the Mercuric Bromide on the test strip to mixed Mercury halogens (such as AsH2HgBr) that appear with a color change from white to yellow or brown. Potassium Peroxymonosulfate is added to oxidize Hydrogen Sulfide to Sulfate.

For better accuracy, we recommend running the test in duplicate for each water sample.

1. For best results, verify that the water temperature is between 68° to 86° F (ideally 71.6° to 82.4° F).

2. To the Reaction Bottle, slowly and carefully add the water sample to the upper marked line on the bottle (100 mL).

3. Add 3 level pink spoonfuls of First Quick TM Reagent to the Reaction Bottle. Cap bottle securely with yellow mixing cap and shake vigorously with bottle upright for 15 seconds.

4. Uncap Reaction Bottle; add 3 level red spoonfuls of the Second Reagent. Cap bottle securely with yellow mixing cap and shake vigorously with bottle upright for 15 seconds.

This step allows the test to tolerate Hydrogen Sulfide (H2S) up to 2ppm (mg/L). If you suspect the presence of H2S by smell or testing, allow the sample to sit for 2 minutes to minimize H2S interference before proceeding to Step 5.

5. Uncap Reaction Bottle and add 3 level white spoonfuls of Third Reagent. Cap bottle securely with yellow mixing cap and shake vigorously with bottle upright for 5 seconds.

6. Remove yellow mixing caps. Recap bottles securely using white reaction caps with turret up (open).

7. Remove Arsenic test strips from the test strip bottle. Immediately recap the test strip bottle. In order for the results to be accurate, the test strip must be oriented correctly, and inserted to the correct depth.

Insert the test strip into the turret:

  • Position the strip so that the test pad and red line are facing the back of the white reaction cap.
  • Insert the strip into the turret until the red line is even with the top of the turret, and close (flip down) the turret. This will hold the test strip in place.

8. Using a timer, time the reaction for 10 minutes. Allow the reaction to occur in an undisturbed, well-ventilated area. You will notice small hydrogen gas bubbles being generated.

9. After the 10 minute wait, pull up the turrets and carefully remove the test strip. Do not touch the reaction pads. Use the Easy-Read Color Chart to match the reaction pad color. Position the reacted test strip pad behind the punched holes, view center of test strip pad through the hole, and confirm precise color match and Arsenic level.

Complete matching within the next 30 seconds. After 30 seconds have elapsed, the colors may begin to change. For best color matching results, use natural daylight; avoid direct sunlight.

NOTE: If your Arsenic level is 200 ppb or above, you can confirm the elevated levels by diluting the water sample 1 to 5. Fill the Reaction Bottle to the bottom marked line with water sample (20 mL) and add Arsenic-free water to the upper marked line. Now run steps 3 thru 10. For your true Arsenic value, multiply the result by 5 to correct for dilution and record the value.

WARNING: Hydrogen and Arsine gases are generated during the test. Work in a well-ventilated area away from open flames and other sources of ignition. Review the Material Safety Data Sheet before handling any chemicals.

SOIL TEST PROCEDURE
(Non-Digestion Method)
Scope and Application:
1. This method is valid for detection of Inorganic Arsenic in soil.
2. The minimum Arsenic detection with 0.5 g of soil is 1.0 mg/kg.
Sample Handling and Preparation (Recommended but not required):
3. Dry soil for at least 1 hour at 60°C or until completely dry.
4. Remove visible debris/stones from dried soil.
5. Grind the dried soil into a fine powder and mix until homogeneous using a coffee grinder or a mortar and pestle.
    (a Coffee Grinder works well)
Interference's:
6. Test tolerates up to 2 mg/kg of Hydrogen Sulfide, 9000 mg/kg of Iron, and 1500 mg/kg of Lead.
Test Procedure:
7. Weigh out 0.5 g of the dried soil and transfer to the Reaction Bottle supplied in the Arsenic Quick™ Kit
    (Part # 481396-5). Note: If the Sample Handling and Preparation steps are omitted, then use 1g of soil. One gram
    is used on assumption that soil is 50% moisture by weight.)
8. Fill the bottle to the upper marked line on the Reaction Bottle with 100 mL of Arsenic-free tap water or Distilled water.
9. Follow the standard test procedure for the Arsenic Quick™ Kit starting with Step 3 on page 3.
Calculation:
10. Multiply the test result by 300 (correction multiplier) to get the Arsenic concentration in the soil as mg Arsenic/kg
      Soil. (Example: 40 μg/L x 300 = 12 mg Arsenic/kg Soil)
NOTE:
Because when compared to Acid Digestion/ICP-MS Arsenic analysis, this soil screening method gives typically
50% lower value; a correction multiplier of 300 is used (use 200 as a multiplier if you desire actual measured level).

Download Instructions & Troubleshooting Guide (PDF format)

UPC: 809762139627
Search Category: Hardware > Tools > Measuring Tools & Sensors
First Product Previous Item Product 9 of 39 Next Item Last Product
Category Water Testing
  Your IP Address is: 3.95.131.97
Copyright Inspect USA®. All rights reserved. 1995-2019
No part of this website may be reproduced without our express consent.
Distributors of TestKits, Inspection Tools, HVAC Smoke & Food Safety Equipment.
Customer Reviews Click for the BBB Business Review of this Mail Order & Catalog Shopping in Marshall NC


Welcome
Login:
eMail Address:
Password:
Forgot Password?
Password Reset
Categories
Air Quality - IAQ

Anemometers-Air Flow

Carbon Monoxide (CO)

EMF / Microwave Meters

Fire and Smoke Safety

Food Safety & Hygiene

Gas and Leak Detectors

Heat Detector Testing

Infrared Thermometers

Inspection Supplies

Light, LUX, UV Meters

Manometers / Pressure

Measuring Instruments

Moisture Detectors

Power & Circuit Testers

Radon Mitigation & Fans

Radon Testing & Supplies

Refractometers - BRIX

Safety and Security

Smoke Trace Emitters

Soil & Grain Meters

Sound Level Meters

Specialty Instruments

Temperature & Humidity

Timers and Clocks

Tools and Hardware

Water & Flood Alarms

Water Testing

Outlet / Clearance
Quick Find

Search Catalog:

Advanced Search
Manufacturers