Smoke Emitter: PERFUMED 600 Cubic Feet (S103-P) 90 Sec. 10 PACK
Regular Price: $26.99 $18.95
Quantity Discounts |
1 | 2-5 | 6-9 | 10-19 | 20+ |
$18.95 | $17.43 | $17.06 | $16.58 | $16.11 |
Perfumed White Smoke Emitter: 600 Cubic Feet (S104-P) Approximate 65-90
Second Burn
Time; 10 Pack
S103-P: 10 Pack of Miniax Perfumed 65-90 Second, 600 Cubic Feet White/Grey non-toxic smoke
emitters. Smoke
emitters provide an inexpensive method of
generating swirling smoke. A great product for testing of high,
medium, and low pressure duct-work systems and also for air balancing. The smoke
emitted does not contain oil nor zinc and will not leave any residue. It is
non-toxic and has the same density as air, so that it is possible to observe
true air movements without the complicating factor of having to allow for the
natural rise or fall of the smoke. The particle size is 0.3 to 2.5 microns making it
ideal to check HEPA filters. The smoke cartridges produce a generous amount of
smoke, which is emitted at a constant rate to help with the identification of
flow patterns.
Features:
- 65 to 90 seconds burn time
- Produces 600 cubic feet of smoke
- Perfumed White/Grey Smoke
- Dimensions: 32mm high x 18mm Ø
- Excellent method to visualize airflow patterns
- Non-toxic smoke candles
- Does not contain oil, zinc, rubber powder or naphthalene
- Leaves no visible residue
- Particle size is 0.3 to 2.5 microns
- Cartridges are enclosed in environmentally friendly plastic housing with
a humidity seal
- 2 year shelf life
- ISO 14001 Certified
Product |
Product # |
Size |
Burn time |
Color |
Volume
|
m3 |
Cubic Feet |
Miniax |
S102-P |
3 gram |
40-45 sec |
White/Grey |
2.5 |
150 |
Miniax KS |
S103-P |
9
gram |
65-90
sec |
White/Grey |
8.5 |
600 |
Ventilax |
S104-P |
18
gram |
3-4
min |
White/Grey |
17 |
1,200 |
Brandax VS |
S105-P |
60
gram |
3-4
min |
White/Grey |
55 |
2,500 |
Applications:
- Testing for leaks in duct work, heat exchangers, furnaces, plumbing
- Testing air movement & ventilation systems
- Turbulence around fume hoods
- Duct mounted smoke detectors
- Fume evacuation from gas heaters, etc
- Ventilation in personal spaces
- Ventilation in stables, poultry farms, etc
- Positioning of smoke detectors
- Leakage in ventilation systems
- Leakage in drainage systems
- Exhaust fans
- Fire drills, training exercises for buildings, rescue & more
- Military training & drills
- Special effects & hobbies
Directions:
- Place cartridge on non-flammable surface. A metal can or bucket with sand in
the bottom is a great way to be safe.
NOTE: maintain at least 3"
between cartridges when several are lit.
- Light open end with a flame from lighter, match etc.
Warning: Poisonous to swallow. To be kept away from children
& animals. Do not use smoke emitters near flammable materials, gas etc.