InspectUSA.com
Features:
- Built in sampling pump with battery saving standby switch
-
Measures: Flue temperature, differential flue temperature, oxygen, flue &
ambient carbon monoxide (CO), and differential pressure
-
Calculates: Carbon dioxide, gross/net efficiency, excess air, CO air free
-
Integrated bright Worklight
- Pre-programmed Fuels: Natural Gas,
Light Oil, Propane, Butane and Liquefied Petroleum Gas
- Heavy duty
stainless steel probe with depth stop
- Automatic calibration
-
Efficiency reading on condensing boilers
- Infrared printer port
-
Back-lit Large 4 line LCD display
- Unique DMM style rotary selector
-
Ruggedized boot with integral magnet
- Real time clock
-
CO readings to 1 ppm
- User programmable header
- 179
memory positions
- User customizable parameters view
- Can
use alkaline or rechargeable NiMH batteries
- Low battery
indicator
- Individual report printouts
- Made in UK
Specifications:
- Flue temperature range*: 20� to 2400� F (-29� to 1315�
C)
- Net ΔT temperature range**: 20� to 2400� F (-29� to 1315� C)
-
Flue temperature & ΔT accuracy: �0.3% reading + 3.6� F (+ 2� C)
-
Inlet temperature range (ambient): 32 to 112� F (0 to 50� C)
-
Ambient temperature accuracy: �0.3% reading + 1.8� F (+ 1� C)
-
Temperature resolution: 1� F/C
- Oxygen O2 range*: 0 to 21%
-
Oxygen O2 resolution: �0.2%
- Oxygen O2 accuracy: 0.1%
-
Carbon Monoxide CO range*: 0 to 4000ppm
- Carbon Monoxide CO
resolution: 1ppm
- Carbon Monoxide CO accuracy: �10ppm <100ppm, �5%
of reading
- Carbon Dioxide CO2 range**: 0 to 30%
- Carbon
Dioxide CO2 resolution: 1.0
- Carbon Dioxide CO2 accuracy: �0.3%
reading
- Efficiency range**: 0 to 99.9%
- Efficiency
resolution: 0.1%
- Efficiency accuracy: �1.0% reading
-
Excess Air range**: 0 to 250%
- Excess Air resolution: 0.1%
-
Excess Air accuracy: �0.2%
- CO/CO2 range**: 0 to 0.999%
-
CO/CO2 resolution: 0.0001%
- CO/CO2 accuracy: �5% of reading
-
Pressure A (differential):
- range: �0.2mBar (0.08" WG)
-
resolution: 0.001mBar
- accuracy: �0.005mBar (�0.002"WG)
-
Pressure B (differential):
- range: �1.0mBar (0.4" WG)
-
resolution: 0.001mBar
- accuracy: �0.03mBar (�0.01"WG)
-
Pressure C (differential):
- range: �80mBar (32" WG)
-
resolution: 0.01mBar
- accuracy: �3% reading
-
Dimensions:
- Handset: 7.9" x 1.8" x 3.5"
- Probe:
Length 11.8" x 0.25" diameter with 8" long stainless steel shaft
-
Neoprene Hose: 9' with 'K' type thermocouple
-
Power: (4) "AA" (designed for both alkaline or rechargeable Nickel Metal
Hydride (NiMH) batteries)
- Battery life: ~12 hours using (4)
alkaline batteries
- AC adapter:
- Input: AC 110v / 220v
nominal
- Output: DC 6v, 500mA
* calculated** measured
Supplied with:
- Eagle 2 (C125) Combustion
Analyzer
- Depth stop cone
- Stainless Steel Flue Probe
-
9' Neoprene hose with incorporated "k" type thermocouple end
-
Ruggedized boot with integral magnet
- Soft Carrying Case with
protective foam interior (AC75)
-
Particle filter (17631)
-
Quick start manual & owners guide
- Three year limited warranty (2
year warranty on sensor)