Reference only — this item is no longer available.
This product has been discontinued and cannot be ordered. We keep the page online so the specifications and documentation stay available to anyone still running the equipment. Current replacements are listed further down.
Discontinued
Product details (archived)
The information below is retained for reference only. This item is discontinued and cannot be ordered.
- Single Thermocouple input
- Data logging intervals can be programmed - 9,999 memory positions
- USB interface (software included)
- Large backlit multi parameter display
- Internal 24 hour clock
- Thermocouple temperature offset
- Accepts J, K, T and E type Thermocouples
- MIN, MAX, AVG & Data Hold
- Convenient probe storage
- °F, K and °C selectable
- Low battery indicator
- Auto power off (can be re-programmed)
- Relative mode
- CE Certified
Specifications:
- Temperature measuring range K-Type Bead: -40° to +900°F (-40° to +480°C)
- Temperature measuring range J-Type Probe: -346° to +2192°F (-210° to
+1200°C)
- Temperature measuring range K-Type Probe: -328° to +2498°F (-200° to
+1370°C)
- Temperature measuring range T-Type Probe: -418° to +752°F (-250° to
+400°C)
- Temperature measuring range E-Type Probe: -238° to +1832°F (-150° to
+1000°C)
- Temperature resolution:
- <1000°: 0.1 °F/°C
- ≥1000°: 1.0 °F/°C
- Accuracy*:
- J, K, T, and E-Type; ±[0.1% +1.0°F (0.5°C)
- Below -148°F (-100°C): add 0.2% of reading for J, K, and E-Type
- 0.1% of reading for T-Type
- Operating temperature range: 14° to 122°F (-10° to 50°C)
- Storage temperature range: -40° to 140°F (-40° to 60°C)
- Temperature Coefficient:
- 0.01% of reading 0.1°F per °F(+0.05°C per °C) for <+64°F (+18°C) or
+82°F (+28°C)
- Below -148°F (-100°C): add 0.05% of reading for J, K, and E-type;
and 0.1% of reading for T-type
- Humidity range:
- Non condensing: <50°F (10°C)
- 85% RH: 50° to 86°F (10° to 30°C)
- 70% RH: 86° to 104°F (30° to 40°C)
- 45% RH: 104° to 122°F (40° to 50°C)
- Altitude:
- Operating: up to 200 m
- Storage: up to 10000 m
- IP67 Water submersion (3’ for 30 min.)
- Real time clock tolerance: about 1 second per day
- High pressure dust resistance (max depression of 20 mbar for 8 hours)
- CAT 1: Overvoltage (Installation) CATEGORY I, Pollution Degree 2 per IEC
1010-1
- Dimensions: 7.20” x 3.70” x 1.70 (H x W x D)
- Weight: approx. 16.2 oz (460 g)
- Power: (2) "AAA" 1.5v
- Certification CE
- Safety:
- IEC 1010-1 (2001), UL 3111-1 (6, 1994)
- EN 61010-1 (2001), CSA C22.2
- No. 1010.1 (1992)
Supplied with:
- (1) J type probe with clip
- 5 year limited manufacturer's warranty
- Software
- 2 AAA batteries
- Quick start guide
*Accuracy is specified for ambient temperatures between 64°F (18°C) and 82°F
(28°C) for a period of 1 year. The above specifications do not include
thermocouple error.
Download User's Manual (PDF format)