The following links, images and information remain available for informational purposes only.


The model 1028 continuous radon monitor is a patented electronic detection device used for the measurement of radon gas. The new model 1028 is intelligently designed to be fully programmable by the user. The large 16 character LED display will guide you through an easy set up process to input the Inspection Company Information, Address, State License numbers and phone numbers. This information will be stored in the memory and print on each report.

A real time clock will allow time and dates to be included in each interval. A 12 hour delay start can be pre-programmed to meet all proficiency program closed building procedures. The monitor will turn itself off when the test is complete. With all new electronics, a single 9 volt battery will test for 300+ hours with out draining. The display will alert you prior to starting the test of the battery status. The power cord will also be adaptable from 110v to 220v power outlets. The software program allows “read only” time and date parameter’s to prevent tampering once the test is complete. Weather and test site conditions can also be added along with customer address and contact information. Add photo images of the monitor location in the home. A USB cable will be provided to plug into a Windows operating system only. A serial port connection is available for both computer downloading and thermal print-outs.

PC software, suitable for printing reports, is included with the instrument. A compact printer that plugs into the monitor is available if an on-site report is required.

Radiation Detector
Diffused Junction photodiode
Model 1028 - One

Power
Operates on 12 VDC supplied by external power adapter universal to 110-230 VAC, 200 mA Internal 9 volt alkaline battery provides100 + hours of operation

Cables
Power cord- standard 6 foot, 3 conductor cable with 3 prong wall plug, USB cable-standard 6 foot, USB connector “a” and USB connector “b”

Construction
Dimension: 4.62 in wide, 8.22 in long 3.92 in high
Weight: Approx. 3 lbs

Computer System Requirements
Computer: Minimum Pentium,1 free USB port
Operating System: Windows 95 or Higher
Firmware: Factory installed in flash memory
Measurement Ranges:
0.1 to 999.9 pCi/l
1000 to 9999 pCi/l
1 to 9999 Bq/m3
10.00 to 99.99 kBq/m3

Measurement Accuracy
± 25% or 1 pCi/l, whichever is greater after 24 hours

Measurement Intervals
Model 1028: 1, 2, 4, 8, 12, 16, 20, 24 hours

Sensitivity
Model 1028: 2.5 cph/pCi/l

Operating Environment
45 to 95 degrees F
0 to 90% relative humidity

User Interface
Control Panel: 16 character LCD with a low power reflective display with .3” character height
Keypad: 6 momentary switches provided in a sealed membrane overlay