This electronic radon detector/monitor is a proven performer being in service since 1996. Used by inspectors, consultants and homeowners to monitor the radon gas levels in schools, offices and residences. It is a solid state continuous radon monitor which utilizes patented technology. At the heart of the device is a measurement circuit and pulse processing software which records alpha events on a photovoltaic sensor. Radon daughters create a spark when they come in contact with the potential across the collection dome and the photovoltaic sensor counts these pulses. The software equates pulse volume into pCi/L (Pico Curies per Liter) and then displays the information on the LED display. Since there is no offal from a pulse event, this measurement device requires no periodic calibration.
- Results will display in approx 48 hrs on a numeric digital LED display (range 0 - 999)
- Shows the level of radon gas in pCi/L on a short-term or long-term basis
- 2 modes of measurement - long & short term
- Alarm sounds if the long-term average reaches 4 pCi/L or greater (can be silenced)
- Samples air continuously; display updated every hour.
- Self-test every 24 hours with an error code displayed if failure.
- 10' power cord supplied
- Menu button controls 4 functions. Re-set unit and use in different locations.
- 10 year sensor and a 1 Year warranty!
|
Power Source Input
|
120v AC / 60Hz at 9 Watts
|
|
Power Source Output
|
18v DC / 200mA
|
|
Sensor
|
Ionization Chamber
|
|
Sensor Voltage
|
250VDC
|
|
Full Scale Reading
|
999 pCi/L
|
|
Rounding
|
Less than whole numbers round down (3.9 = 3 displayed)
|
|
Operating Environment
|
0°C (32°F) to 70°C (158°F)
|
|
Storage Environment
|
-20°C (-4°F) to 85°C (185°F)
|
|
Audible Alarm
|
85dB at 10cm. Beeps every hour if long-term readings are 4 pCi/L or greater.
|
|
Averaging Frequency
|
Levels will be updated on the display every hour.
|
|
Short-Term
|
Average over the past 7 days.
|
|
Long- Term
|
Average from the time of last reset (5 year max) resets after 5 years.
|
|
Accuracy
|
+/- 12% pCi/L
|
|
Dimensions
|
4.7" x 3.1" x 2.1"
|