Meters, Test Kits, Inspection Supplies & Tools!

RadonAway Low Voltage Pro-Series 4" (LV175) 24 Volts Radon Fan

Model #: 28537

Condition: New

Item may vary slightly from image.

$325.53

Add Qty to Cart:
Product 10 of 36
Category: Radon / VOC Fans

RadonAway LV175 Pro Series Low Voltage Radon Fan, 24 Volts

RadonAway LV175 Low Voltage Radon Fan includes a power supply equipped with a 2-prong power cord for connecting to 120v AC power and a weather-tight, locking two-pin DC connector for connecting the power supply to the fan. No additional electrical work is required.

  • 24 VDC fan operation.
  • Pro Series Stay White™ Housing.
  • Water-tight fittings included; fan is factory sealed – no additional caulk or sealants required.
  • 1.9" Maximum Recommended Operating Pressure (WC) at sea level. Reduce by 4% for every 1,000 feet of elevation and by 10% for high temperature operation.
  • ETL Listed for Indoor and Outdoor Use. Conforms to UL STD. 507; certified to CAN/CSA STD. C22.2 No. 113.
  • The LV175 Pro Series Fan can provide coverage up to 2000+ sq. ft. per slab penetration. This will primarily depend on the sub-slab material in any particular installation. In general, the tighter the material, the smaller the area covered per penetration. Additional suction points can be added as required. It is recommended that a small pit (5 to 10 gallons in size) be created below the slab at each suction hole.
  • Thermally protected.
  • Continuous duty.
  • Mounts directly on system piping or with optional mounting bracket (RadonAway P/N 25007).

Do not install or mount the power supply outdoors. Fan must be mounted vertically plumb and level with the outlet pointing up. Not suitable for underground burial.

Specifications:

  • P/N: 28537.
  • Inlet/Outlet: 4.5" outside diameter.
  • Power Consumption 120VAC, 60Hz, 1.1 Amp Maximum: 30 to 75 watts.
  • 3900 RPM.
  • Dimensions: 8.5" Height x 9.7" Diameter.
  • Net weight: 5.5 pounds.
  • Recommended duct: 3" or 4" Schedule 20/40 PVC.
  • L.2: 15
    L.2 = Estimated Equivalent Length of Rigid Metal Ducting resulting in .2" WC pressure loss for Duct Size listed. Longer Equivalent Lengths can be accommodated at Flows Lower than that at .2" WC pressure loss (see CFM Vs Static Pressure "WC Table).
  • Thermal cutoff: 266°F (130°C).
  • Insulation Class: Class F.
TYPICAL CFM vs. STATIC PRESSURE in inches of (WC)
0" 0.25" 0.5" 0.75" 1.0" 1.25" 1.5" 1.75" 2.0"
216 195 176 156 135 114 90 45 -

Supplied with:

  • Installation instructions.
  • Power supply equipped with a 2-prong power cord for connecting to 120v AC power with:
    • Weather-tight, locking 2-pin DC connector for connecting the power supply to the fan.
  • Manufacturer's limited warranty: 6 months from date of purchase (12 months from date of manufacture, whichever is sooner). Extended to 2 years from date of purchase when installed by a professional radon mitigation contractor. Extended to 2 years from date of purchase when purchased from InspectUSA.