Meters, Test Kits, Inspection Supplies & Tools!

TPI Digital Multimeter (TP-120) Discontinued

TPI Digital Multimeter (TP-120)

Reference only — not for sale

ModelTP-120
ManufacturerTPI
CategoryMultimeters / LCR
StatusDiscontinued
Browse all Multimeters / LCR Ask us for a replacement

Product details (archived)

The information below is retained for reference only. This item is discontinued and cannot be ordered.

TPI Digital Multimeter (TP-120)

Compact, manual ranging, basic DCV 0.5% accuracy DMM.

The TPI Model 120 is a Compact, manual ranging, basic DCV 0.5% accuracy DMM.

Usage Tip: When using the Model 120, press the DATA-H button at any time on any function or range to freeze the reading on the LCD display. This function is very useful when measuring in locations where the display is difficult to read.

  • Safety: Meets CE and IEC 1010 requirements. UL Listed.
  • Large LCD: Easy to read at all angles and the majority of lighting levels.
  • Data Hold: Freeze readings on the display.
  • Rubber Boot: Added protection when the instrument is dropped. (120NB does not include boot.).
  • Versatile: Use accessories like a carbon monoxide attachment to expand the capabilities of the 120.2,000 count display.
  • cULus 61010-1.
  • CAT II – 1000V, CAT III – 600V.
  • 0 to 600 volts AC and DC.
  • 0 to 2,000 ohms.
  • Audible continuity.
  • 10 MOHM internal impedance.
  • 0.5 % DCV basic accuracy.

Specifications

  • DC Volts: Maximum Input: 600V (Minimum Input = 1.5V) Maximum Resolution: 0.001V Accuracy: +/-0.5%.
  • AC Volts: Maximum Input: 600V (Minimum Input = 1.7V) Maximum Resolution: 0.1V Accuracy: +/-0.8%.
  • DC Amps: N/A.
  • AC Amps: N/A.
  • Resistance (Ohms): Maximum Input: 2KΩ Maximum Resolution: 0.001Ω Accuracy: +/-0.5%.
  • Frequency: N/A.
  • Capacitance: N/A.
  • Inductance: N/A.
  • Temperature (K-Type Thermocouple): N/A.
  • Continuity: Audible at less than 100Ω.
  • Diode: N/A.
  • Duty Cycle: N/A.
  • True RMS Responding: No.
  • Conductance: No.
  • Pulse Width: No.
  • Data Hold: Yes.
  • Min/Max Record: No.
  • Time Stamp Logging: No.
  • Relative Mode: No.
  • Compare Mode: No.
  • RS-232 Output: No.
  • Process Loop Output: No.
  • Sleep Mode / Auto Off: No.
  • Protective Boot: Yes (standard).
  • Display Type: 2000 count LCD.
  • Range Selection: Manual.
  • Operating Temperature: 32°F to 104°F (0°C to 40°C).
  • Storage Temperature: 14°F to 122°F (-10°C to 50°C).
  • Humidity: 80% non-condensing.
  • Size: 6" x 3.1" x 1.2" (187mm x 86mm x 33mm) with boot.

Available replacements in Multimeters / LCR

Looking for something specific?

0 items
Manufacturers