Indoor Air Quality Meter with Internal Datalogger
- Measures CO2 , Temperature, Humidity, Dew Point, and Wet Bulb
- Checks for Carbon Dioxide (CO2) concentrations
- Maintenance free dual wavelength NDIR (non-dispersive infrared) CO2 sensor
- Continuous (20,000 sets) or Manual (99 sets) data logging
Specifications:
- Relative Humidity Range: 10 to 95%RH
- Resolution: 0.1%RH
- Accuracy:
- ±3%RH at 25°C (77°F) and 30 to 95% RH
- ±5%RH at 25°C (77°F) and 10 to 30% RH
- Sensor type: Precision capacitance sensor
- Response time:
- 45 to 95%RH ≤ 1 minute
- 95 to 45%RH ≤ 3 minutes
- Temperature Range: -20° to 60°C (-4° to 140°F)
- Resolution: 0.1°
- Accuracy: ±0.5°C, ±0.9°F
- Sensor type: Thermistor
- Response time: approximately 2 seconds at 10°C
- Display: LCD triple display
- Display Rate: One time per second
- Low Battery Indication: The '+' is displayed when the battery voltage drops below the operating voltage
- Power Supply: (6) AAA batteries or Regulated AC adapter
- Battery Life: Approx. 8 hours by using alkaline batteries (without backlight or Alarm function). If data logging over a long period of time, use an AC adapter.
- Manual Data Memory Capacity: 99 sets.
- Auto Data logging Capacity: 20,000 sets (maximum 99 blocks)
- Operating Temperature Range: 5° to 50°C (41° to 122°F)
- Storage Temperature Range: -10° to 60°C (-14° to 140°F)
- Operating Humidity Range: 10 to 90%RH
- Storage Humidity Range: 10 to 90%RH
- Dimensions: 6.22" x 2.83" x 1.38"
- Weight: approx 255g (including batteries)
CO2 Specifications:
- Sensing Range: 0 to 6000ppm
- Resolution: 1ppm
- Accuracy: ±3% of reading at 101.4 kPa (29.92 inHg) and 25°C (77°F) or ±50ppm, whichever is greater
- Sensing Method: Dual wavelength detector with non-dispersive infrared (NDIR) sensor
- Gas Sampling Mode: Diffusion
- Warm up time: 10 seconds
- Response time: <10 minutes in still air
- Temperature Coefficient: Add 0.36% of reading per °C (±0.2% of reading per °F) away from calibration temperature
Supplied with:
- Instruction Manual
- (6) AAA batteries
- AC Adapter
- Software CD ROM Windows 95/98/NT/2000/ME/XP compatible software
- RS232 Cable
Download Users Manual (PDF format)