Meters, Test Kits, Inspection Supplies & Tools!

UEI Combustion Analyzer O2 CO2 & CO (C155) SS Probe, Hose & Case Discontinued

UEI Combustion Analyzer O2 CO2 & CO (C155) SS Probe, Hose & Case

Reference only — not for sale

ModelC155
ManufacturerUEI
CategoryLeak Detectors
StatusDiscontinued
Browse all Leak Detectors Ask us for a replacement

Product details (archived)

The information below is retained for reference only. This item is discontinued and cannot be ordered.

The UEI C155 Eagle 2X UEI EOS eXtended Life Combustion System Analyzer 4 instruments in 1. The newly redesigned Eagle 2X Combustion System Analyzer eliminates the number one hassle for combustion contractors; the annual replacement and calibration of the O2 sensor. By replacing the electro chemical O2 sensor with the EOS Technology™ CO2 sensor, the EAGLE 2X now takes direct CO2 measurements and calculates the O2 level. This lowers the cost of ownership by doing away with the annual replacements of the O2 sensor and reducing calibration drifting typically found with standard electro-chemical sensors. The EOS Technology sensor is warranted for 5 years and has an unmatched industry-leading life expectancy of 10 years!

Features:

  • Measures: Differential flue temperature, Carbon Dioxide CO2, flue & ambient carbon monoxide CO & Differential Pressure
  • Calculates: Oxygen O2, gross/net efficiency, excess air, & CO air free
  • Worklight
  • Large 4 line backlit LCD display
  • 179 memory positions
  • User customizable parameters view
  • Individual report printouts
  • Unique DMM style rotary selector
  • Protective boot with integral magnet
  • Real time clock with date & time stamp
  • CO readings to 1ppm
  • Infrared printer port
  • 5 year limited manufacturers warranty (including sensor)
  • Battery level indicator

Specifications:

Flue Temp Range: 20° to 2400°F (-29° to 1315°C)
Inlet Temp Range: 20° to 2400°F (-29° to 1315°C)
Inlet Temp Range (Ambient): 32° to 112°F (0° to 50°C)
Net Temp (DELTA-T):** 20° to 2400°F (-29° to 1315°C)
Oxygen O2:** 0 to 21%
Carbon Monoxide CO:* 0 to 2000ppm (4000 max 15 min)
Carbon Dioxide CO2:* 0 to 20%
Efficiency**: 0 to 99.9%
Excess Air**: 0 to 250%
CO/CO2:** 0 to 0.999%
Nitric Oxide NO1: Available on C157 & C157KIT
Pressure (Differential) Accuracy
±0.08" wc (±0.2mBar) 0.001mBar / ±0.005mBar ±0.002"wc
±0.4" wc (±1mBar) 0.001mBar / ±0.03mBar ±0.01"wc
±32" wc (±80mBar) ±3% reading
Pressure resolution: 0.001"wc < 9.999"wc
0.01"wc >10.00"wc
0.001mBar <24.999mBar
>25 mBar

* Measured at STP (standard temperature and pressure)
** Calculated valueElectro Optical Sensor Technology

  • Weight: 2.2lbs. with boot
  • Handset: 7.9" x 1.8" x 3.5"
  • Probe: 11.8" x 0.25" x 9.4" stainless steel shaft, type K thermocouple (9' hose)
  • Operating temperature range: 32° to 104°F (0° to 40°C)
  • Operating humidity range: 10 to 90% RH non-condensing
  • Power: 4 AA cells / 12 hour life typical with Alkaline AA cells
  • Pre-Programmed Fuels: Natural Gas, Propane, Butane, LPG, Light and Heavy Oil, Bio-Fuel, Wood

Includes:

  • C155 Analyzer
  • Depth stop cone
  • Flue Probe
    • Flue draft
    • Gas pressure
  • 9' Neoprene hose with incorporated "k" type thermocouple end
  • Ruggedized boot with integral magnet
  • Particle filter 17631
  • Hard shell carrying case AC509
  • Quick & Users start manual
  • (4) AA alkaline batteries
  • 5 year limited manufacturers warranty (including sensor)

Download Users manual (PDF format)
Download QUICK START manual (PDF format)
Download C155/C157 Data Sheet (PDF format)

Available replacements in Leak Detectors

Looking for something specific?

0 items
Manufacturers