Meters, Test Kits, Inspection Supplies & Tools!

Safety Siren Radon Gas Monitor & Alarm (HS71512) Discontinued

Safety Siren Radon Gas Monitor & Alarm (HS71512)

Reference only — not for sale

Modelpro3
ManufacturerFamily Safety
CategoryRadon Testing
StatusDiscontinued
Browse all Radon Testing Ask us for a replacement

Product details (archived)

The information below is retained for reference only. This item is discontinued and cannot be ordered.

THIS ITEM IS NO LONGER AVAILABLE.

Upgraded BY MANUFACTURER to Pro Series 4. Link for New Pro Series 4

The following links, images and information remain available for informational purposes only.



The Pro Series 3 electronic radon gas monitor & alarm meets EPA Performance Criteria of the CR protocol.

Our electronic radon gas detector/monitor is a proven performer being in service since 1996. Used by inspectors, consultants and homeowners to monitor the radon gas levels in schools, offices and residences. It is a solid state continuous radon monitor which utilizes patented technology. At the heart of the device is a measurement circuit and pulse processing software which records alpha events on a photovoltaic sensor. Radon daughters create a spark when they come in contact with the potential across the collection dome and the photovoltaic sensor counts these pulses. The software equates pulse volume into pCi/L (Pico Curies per Liter) and then displays the information on the LED display.
  • Made in the U.S.A.
  • No wiring or batteries needed, uses typical 110v household current
  • Entela Certified
  • Results will display in approx 48 hrs on a numeric digital LED display
  • Shows the level of radon gas in pCi/L on a short-term or long-term basis
  • 2 modes of measurement - long & short term
  • Alarm sounds:
    • Long-term measurement reaches 4 pCi/L or greater (can be silenced)
    • Short-term measurement stays above 4 pCi/L for 30 consecutive days
  • Samples air continuously; display updated every hour.
  • Self-test every 24 hours with an error code displayed if failure.
  • 10' power cord supplied
  • Menu button controls 4 functions. Re-set unit and use in different locations.
  • UL61010B-1:2003 Issued: 1/24/03 Ed: 1 Standard for Safety Electrical Measuring & Testing Equipment; Part 1: General requirements
  • CSA C22.2 NO 1010.1-92 - Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use, Part 1: General requirements
  • 10 year sensor and a 1 Year warranty

Specifications:

  • Sensor: Ionization Chamber
  • Sensor voltage: 250vDC
  • Full scale reading: 0.1 to 999.9 pCi/L
  • Operating temperature: 32° to 104° F (0° to 40° C)
  • Storage temperature: -4° to 185° F (-20° to 85° C)
  • Audible Alarm: 85dB at approximately 10' away
  • Beeps every hour if:
    • long-term readings are 4.0 pCi/L or greater or
    • short-term measurement stays above 4.0pCi/L for 30 consecutive days
  • Averaging frequency: Levels will be updated on the display every hour
  • Short-Term: Average over the past 7 days
  • Long-Term: Average from the time of last reset (5 year max) resets after 5 years
  • Accuracy: ±88% pCi/L (click here to see accuracy report in PDF format)
  • Dimensions: 4.7" x 3.1" x 2.1"
  • Follow this link for more technical info (will open in new window)

Supplied with:

Call for quantity discounts. Contact Us

Available replacements in Radon Testing

Looking for something specific?

0 items
Manufacturers