Meters, Test Kits, Inspection Supplies & Tools!

Compact Sound, Temp, RH Meter (EM-1910) Plus Heat Index

Model #: EM-1910

UPC: 00810106420783

Condition: New

Item may vary slightly from image.

List Price: $225.99 $162.00

Ordering more than the quantity shown in stock?
Quantities above the quantity shown in stock will ship on or before 10/12/26 - 10/26/26. Orders ship complete by default — if you would like the in-stock portion shipped separately, please indicate at checkout. Ordering the full quantity in one transaction receives the best pricing and any applicable quantity discounts on the total ordered. Learn more about special orders and split shipments.
Add Qty to Cart:

3 × AAA batteries

Product 10 of 18
Category: Sound Meters

Compact 7-in-1 Sound Meter (EM-1910) Plus Environmental Conditions

Measures sound level, humidity, temperature, light, dew point, wet bulb, heat index, and Type K thermocouple temperature with an optional probe

The Lutron EM-1910 combines seven professional environmental instruments in one hand-held meter: sound level, humidity/temperature, light, dew point, wet bulb, heat index, and Type K thermocouple temperature with an optional probe. The slim bone-shaped case is built for one-hand operation, and a high precision humidity sensor with fast response time feeds the calculated dew point, wet bulb and heat index readings. Certified to ISO-9001, CE and IEC 1010.

  • Seven instruments in one: sound level meter, humidity/temperature, light meter, dew point, wet bulb, heat index, and Type K temperature (optional probe).
  • Tiny bone shape with light weight and small case size, suitable for one-hand operation.
  • Wristlet design provides extra protection to the instrument, especially during one-hand operation.
  • High precision humidity sensor with fast response time.
  • Built-in microprocessor circuit assures excellent performance and accuracy.
  • Concise and compact button arrangement for easy operation.
  • Memorizes the maximum and minimum values with recall.
  • °C / °F selection by pressing a button on the front panel.
  • Hold function freezes the current reading value.

Specifications

Display 14 mm LCD display.
Measurement 1. Sound level meter. 2. Humidity/temperature. 3. Dew point. 4. Wet bulb. 5. Heat index. 6. Light meter. 7. Type K temperature (optional).
Operating humidity Max. 80% RH.
Operating temperature 0 to 50 °C (32 to 122 °F).
Over input display Indication of "- - - -".
Power supply UM4-AAA x 3 (DC 4.5V battery).
Power consumption Approximately DC 18 mA.

Electrical Specifications

Specifications apply at 23 ± 5 °C.

Sound Level Meter

Measurement range 35 to 130 dB
Resolution 0.1 dB
Frequency 31.5 to 8,000 Hz
Function Data hold; record maximum and minimum.
Microphone type Electret condenser microphone.
Microphone size 12.7 mm outside diameter (1/2").
Accuracy Characteristics of the "A" frequency weighting network meet IEC 61672-2013 class 2. Under a 94 dB input signal, accuracy is as listed below.
Frequency Accuracy
31.5 Hz± 3.0 dB
63 Hz± 2.0 dB
125 Hz± 1.5 dB
250 Hz± 1.5 dB
500 Hz± 1.5 dB
1 kHz± 1.0 dB
2 kHz± 2.0 dB
4 kHz± 3.0 dB
8 kHz± 5.0 dB

Humidity and Temperature

Unit Range Resolution Accuracy
% RH 10% to 95% RH 0.1% RH Below 70% RH: ± 4% RH. At 70% RH and above: ± (4% of reading + 1.2% RH).
°C 0 to 50 °C 0.1 °C ± 1.2 °C
°F 32 to 122 °F 0.1 °F ± 2.5 °F

Light

Unit Range Resolution Accuracy
Lux 0 to 2,200 Lux 1 Lux ± 5% of reading ± 8 digits
1,800 to 20,000 Lux 10 Lux
Ft-cd 0 to 204.0 Ft-cd 0.1 Ft-cd
170 to 1,860 Ft-cd 1 Ft-cd

Light measurement is auto ranging. Ft-cd is foot-candles.

Dew Point Temperature

Unit Range Resolution
°C -25.3 to 49.0 °C 0.1 °C
°F -13.5 to 120.0 °F 0.1 °F

Dew point is calculated from the humidity and temperature values.

Wet Bulb Temperature

Unit Range Resolution
°C -5.4 to 49.0 °C 0.1 °C
°F 22.2 to 120.0 °F 0.1 °F

Wet bulb temperature is calculated from the humidity and temperature values.

Heat Index

Unit Range Resolution Accuracy
°C 0 to 100.0 °C 0.1 °C ± 2.0 °C
°F 32 to 212 °F 0.1 °F ± 3.6 °F

Type K Thermometer (Optional Probe)

Resolution Range Accuracy
0.1 °C -50.0 to 1300.0 °C ± (0.4% + 0.5 °C)
-100.0 to -50.1 °C ± (0.4% + 1 °C)
0.1 °F -58.0 to 2372.0 °F ± (0.4% + 1 °F)
-148.0 to -58.1 °F ± (0.4% + 1.8 °F)

Specifications are tested in an environment with RF field strength less than 3 V/m and frequency less than 30 MHz.

Heat Index Reference

Celsius Fahrenheit Effect (shade values)
27 to 32 °C 80 to 90 °F Caution: fatigue is possible with prolonged exposure and activity. Continuing activity could result in heat cramps.
32 to 41 °C 90 to 105 °F Extreme caution: heat cramps and heat exhaustion are possible. Continuing activity could result in heat stroke.
41 to 54 °C 105 to 130 °F Danger: heat cramps and heat exhaustion are likely; heat stroke is probable with continued activity.
Over 54 °C Over 130 °F Extreme danger: heat stroke is imminent.

Exposure to full sunshine can increase heat index values by up to 8 °C (14 °F).

Dimensions

Meter (H x W x D) 179 x 57 x 24 mm (7.0 x 2.2 x 0.94")

Weight

Meter only 146 g (0.32 lb)

Accessories Included

  • Instruction manual, 1 pc.

Optional Components

  • Type K temperature probes: TP-01, TP-02A, TP-03, TP-04.

Downloads

Appearance and specifications are subject to change without notice. 190806-EM-1910

Lutron Calibration Certificate
Lutron Certificate of Calibration Lutron Instruments & Solutions arrive brand new from Lutron with this factory calibration certificate enclosed. Until our chain of custody is broken we are certain and guaranty that every meter meets this standard at the time of shipment. InspectUSA would need to ship the new meter directly to your NIST lab, with our guaranty that it would meet NIST standards. We must ship the instrument direct to an approved NIST lab for this guaranty to be applicable. Once the chain of custody is broken for whatever reason, this guaranty is no longer valid.

Search Category: Hardware > Tools > Measuring Tools & Sensors > Sound Meters

Product 10 of 18
Category: Sound Meters
0 items