The C50 Combustion Analyzer helps technicians achieve combustion efficiency quickly, accurately, and easily! Perfect for residential and light commercial efficiency testing and tuning of furnaces, and hot water heaters.
Features:
- Built in sampling pump with battery saving
standby switch
- Calculates CO2
(Carbon Dioxide) gross & net efficiency, and excess air
- Measures O2
(Oxygen)
- Measures flue, inlet & net temperatures
- Pre-programmed Fuels Natural Gas, Light
Oil, Propane, Butane and Liquefied Petroleum Gas, Coke, Heavy Oil, Coal and
Anthracite
- Heavy duty stainless steel probe with
depth stop
- Automatic calibration
- Efficiency reading on condensing boilers
- 16 position memory
- Choose combustion
parameter with a rotary selector
- Measure flue temperature
and oxygen
- Protected boot with an
integral magnet
- Infrared printer port
- User Programmable header
for printed reports
- Day, time and date stamp for printed
reports
- Large backlit LCD, 2 line display
- Battery level indicator
- Made in UK
Specifications:
- Temperature measurement range: 32° to
1112° F (0° to 600° C)
- Temperature resolution: 1° F/C
- Temperature accuracy: ±5° F/C ,
±0.3% reading
- Oxygen O2
measurement range: 0 to 21%
- Oxygen O2
measurement resolution: ±0.2%
- Oxygen O2
measurement accuracy: 0.1% *1
- Carbon Dioxide CO2 measurement range*2:
0 to 30%
- Carbon Dioxide CO2 measurement resolution: 0.1%
- Carbon Dioxide CO2 measurement accuracy: ±0.3% reading
- Efficiency measurement range*2:
0 to 99.9%
- Efficiency
measurement resolution: 0.1%
- Efficiency
measurement accuracy: ±1.0% reading
- Excess Air measurement range*2:
0 to 250%
- Excess Air
measurement resolution: 0.1%
- Excess Air
measurement accuracy: ±0.2%
- Dimensions:
- Handset: 8: x 2" x 3.5"
- Probe: L 12" x Dia .25" with 8" long
stainless steel shaft
- Neoprene Hose: 9' with 'K' type
thermocouple
- Three year
limited warranty (Two year limited warranty on sensors)
- Power: (4) "AA" (designed for both
alkaline or rechargeable Nickel Metal Hydride (NiMH) batteries)
- Battery life: ~8 hours using (4) alkaline
batteries
- Optional AC adapter:
- Input: AC 110v / 220v nominal
- Output: DC 6v, 500mA
Supplied with:
- Depth stop cone
- (4) "AA" alkaline batteries
- Owner's manual
- Combustion efficiency calculation charts
- Protective Ruggedized Boot with integral
magnet
- 9' Neoprene hose with incorporated "k"
type thermocouple end
Optional accessories & replacement parts:
- Infrared printer (KMIRP)
- Soft carrying case (AC75)
- AC adapter (AACA4)
- Replacement particle filter (17631)
- Smoke pump test kit (SPT1)
*1 calculated