Reference only — this item is no longer available.
This product has been discontinued and cannot be ordered. We keep the page online so the specifications and documentation stay available to anyone still running the equipment. Current replacements are listed further down.
Discontinued
Product details (archived)
The information below is retained for reference only. This item is discontinued and cannot be ordered.
SOLO 424 Corded Heat Detector Test Head (SOLO-424) 220/240 volts AC
The SOLO 424 is a professional and robust tool for testing heat detectors
fitted at heights up to 9m / 30ft. Unlike the SOLO
461, it does require a power cord / mains lead but, conversely, does not
require any special energy saving features.
- Quick activation times.
- Lightweight and easy to use.
- Detector types:
- spot.
- point type.
- fixed temperature.
- rate-of-rise.
- combination detectors up to
194°F / 90°C.
- Universal design suits widest range of detectors.
- Supplied with 16ft / 5m cable (additional 16ft / 5m cable available).
- Operating voltage: 220 to 240 volts AC.
- Power: approximately 700 watts.
- Frequency: 50 / 60 Hz.
- Weight: 2 pounds 6 ounces (1.20kg).
- Dimensions:
- Inside diameter: 4.5" (115mm).
- Working depth: 5.9" x 2.4".
- Safety: thermal cut out, electrically fused, double insulated.
Looking for the 110/120 vAC version
SOLO 423
Accessories and poles:
-
SOLO 100 Fiberglass 4 Section Telescopic Pole 14.7 feet.
-
SOLO 108 Fiberglass 2 Section Telescopic Pole 7.8 feet.
-
SOLO 101 Fiberglass Extension Pole 3.7 feet.
-
SOLO 200 Universal Detector Removal Tool.
-
SOLO 610 Protective Carrying Bag.
Instructions for Use
- Before use, check label for correct voltage supply.
- Tester is supplied with a short lead at the end of which is fitted a male industrial safety plug.
- Operator will need to provide extension cable of the necessary length fitted with a female coupling.
- Press the red switch which will then illuminate to indicate the unit is operational.
- Tester cup should be placed completely over the detector (where detector size allows) until the
detector activates.
- Hold in place until alarm occurs, or the LED of the detector flashes (may take up to 60 seconds
for some grades of heat detectors).
WARNINGS
- Do not use on Non-Restorable Heat Detectors (Solo 461
is recommended).
- Do NOT touch metal grill inside the transparent cup during operation, or for several minutes after
testing.
- Do not obstruct air vents on housing.
- Do not use device near surfaces or objects which may be damaged or react to temperatures of
approximately 212°F.
- Use device only in the manner described and intended.
- No unqualified person should attempt to repair or replace parts.