Meters, Test Kits, Inspection Supplies & Tools!

UEI Combustion Analyzer O2 CO2 & CO (C127) SS Probe, Hose & Case Discontinued

UEI Combustion Analyzer O2 CO2 & CO (C127) SS Probe, Hose & Case

Reference only — not for sale

ModelC127
ManufacturerUEI
CategoryLeak Detectors
StatusDiscontinued
Browse all Leak Detectors Ask us for a replacement

Product details (archived)

The information below is retained for reference only. This item is discontinued and cannot be ordered.

The C127 Combustion Analyzer by UEI is 4 instruments in 1. Designed to offer advanced system analysis and productivity. This multi-functional instrument is a superior combustion analyzer with unmatched simplicity and a unique combination of features to enhance a technician's efficiency and safety. The Eagle 3 is perfect for combustion efficiency analysis but also doubles as a differential thermometer, differential manometer, and an ambient CO detector. Offers the same benefits of the Eagle 2 (C125) with the additional ability to measure Nitric Oxide (NOx). This allows technicians to work in commercial and light industrial applications measuring Nitric Oxide at 1ppm resolution.
  • Measures flue temperature, oxygen, carbon monoxide (CO), Differential and Nitric Oxide (NOx)
  • Calculates: Carbon dioxide CO2 , gross / net efficiency, excess air, CO air free
  • Built-in Worklight
  • Unique DMM style rotary selector
  • Protective boot with integral magnet
  • Real time clock with date & time stamp
  • CO readings to 1ppm
  • Large 4 line back-lit display
  • User programmable header
  • 179 memory position
  • User customizable parameters view
  • Individual report printouts
  • Infrared printer port
Specifications:
  • Flue & Inlet Temp Range: 20° to 2400°F (-29° to 1315°C)
  • Inlet Temp Range (Ambient): 32° to 122°F (0° to 50°C)
  • Net Temp (DELTA T):** 20° to 2400°F (-29° to 1315°C)
  • Resolution: 0.1°
  • Flue (T1, Inlet T2, & Net DELTA T) Accuracy: ±[0.3% reading + 3.6°F (2°C)]
  • Inlet Temp Ambient Accuracy: ±[0.3% reading + 1.8°F (1°C)]
  • Oxygen O2: 0 to 21%
  • Carbon Monoxide CO: 0 to 2000ppm (4000 max 15 min)
  • Carbon Dioxide CO2: 0 to 30%
  • Efficiency: 0 to 99.9%
  • Excess Air: 0 to 250%
  • Excess Air Resolution/Accuracy: 0.1% / ±0.2% reading
  • CO/CO2: 0 to 0.999%
  • Nitric Oxide NOx: 0 to 100ppm
  • Weight: 2.2lbs. with boot
  • Handset: 7.9" x 1.8" x 3.5"
  • Probe: 11.8" x 0.25" x 9.4" stainless steel shaft, type K thermocouple (9' hose)
  • Operating temperature range: 32° to 104°F (0° to 40°C)
  • Operating humidity range: 10 to 90% RH non-condensing
  • Power: 4 AA cells / 12 hour life typical with Alkaline AA cells
  • Pre-Programmed Fuels: A Natural Gas, Propane, Butane, LPG, Light Oil
* calculated ** measured

Includes:
  • C127 Analyzer
  • Depth stop cone
  • Flue Probe
    • Flue draft
    • Gas pressure
  • 9' Neoprene hose with incorporated "k"
  • Ruggedized boot with integral magnet
  • (4) AA alkaline batteries
  • Particle filter (17631)
  • Hard shell carrying case AC509
  • Quick & Users start manual
  • 3 year limited manufacturers warranty (2 year sensor warranty)