| Model | 28317 |
|---|---|
| Manufacturer | RadonAway |
| Category | Radon / VOC Fans |
| Status | Discontinued |
| Replaced by | RadonAway VOC Mitigation Fan (GP500) 3" Box-Type Low Profile |
The information below is retained for reference only. This item is discontinued and cannot be ordered.
| Model | P/N | Fan Duct Diameter | Watts | Max Pressure "WC |
|---|---|---|---|---|
| SF180 | 28317 | 3" or 4" | 53-71 | 2.1 |
| Pipe Size | Typical CFM vs. Static Pressure WC | ||||
|---|---|---|---|---|---|
| 0" | 0.5" | 1.0" | 1.5" | 2.0" | |
| Using 4" | 149 | 127 | 96 | 61 | - |
| Using 3" | 119 | 101 | 77 | 49 | - |
* Our specially designed PVC offset coupling is for use when adapting the SF180 to 3" PVC The offset coupling must be used when adapting to 3" pipe to prevent excessive condensation build-up in the fan. The fitting is 4.5" in diameter and has a 3.5" diameter socket to accept 3" PVC . When installed properly, the coupling allows for condensation drainage from the bottom of the fan straight through to the PVC pipe.
The offset can also be used on the discharge side of the fan to maintain the proper spacing allowing the installer to run the stack straight up out of the fan without the need for other fittings. The offset connects to the SF180 using standard 4 x 4 couplings. Use 4" x 4" couplings with 4" pipe and with 3" pipe when using the #13165. Additionally we suggest using the white coupling install kit #28036 to compliment the attractive install of the stay-white SF180.