Discontinued
Reference only — not for sale
| Model | K905CONOX |
|---|---|
| Manufacturer | Kane May |
| Category | Leak Detectors |
| Status | Discontinued |
The information below is retained for reference only. This item is discontinued and cannot be ordered.
The K905CONOX handheld analyzer is easy to use for domestic and industrial boiler flue gas measurement and analysis. It operates on all boiler types and can display 8 parameters simultaneously showing measurements and calculations of boiler efficiency and pollution. It measures O2, flue and NETT temperature and calculates CO2, boiler efficiency, excess air and losses. CO is measured with a hydrogen compensated sensor for increased accuracy. The K905 measures CO and calculates CO/CO2 ratio (The Poison Index) to give complete readings for effective boiler analysis and safety.
Includes seven preprogrammed fuels with two positions for user-specified fuels. With 150 memory locations, tests can be stored and downloaded to the optional IR printer through the infrared port or to a PC through the RS-232 port utilizing the optional Fireworks™ software package. The unit comes complete with a large carrying case, probe and battery charger.
Features:
| Resolution | Accuracy | Range | ||
| Temp Measurement | ||||
| Flue Temperature with Probe | 0.1 degrees |
±2 degrees C ±0.3% |
32-1112 degrees F (0-600 degrees C) | |
| Inlet Temperature | 0.1 degrees |
±1 degrees C ±0.3% |
32-122 degrees F (0-50 degrees C) | |
| Gas Measurement * | ||||
| Oxygen O2 | 0.1% |
±0.2% |
0 to 21% | |
|
Carbon Monoxide CO (H2 compensated) |
1ppm |
±20ppm <400ppm** ±5% <5,000ppm ±10% <5,000ppm |
0 to 10,000ppm | |
| Nitric Oxide - NO1 | 1ppm |
±5ppm<100ppm ±5%>100ppm |
0 to 5,000ppm | |
| Sulfur Dioxide - SO2 | 1ppm |
±5ppm<100ppm ±5%>100ppm |
0 to 5,000ppm | |
| Calculations | ||||
| Carbon Dioxide CO2 * | 0.1% |
±0.3% |
0 to 99.9% | |
| Losses ** | 0.1% |
±1.0% |
0 to 99.9% | |
| Efficiency ** | 0.1% |
±1.0% |
0 to 99.9% | |
| Excess Air ** | 0.1% |
±0.2% |
0 to 2885.0% | |
| Temp (Nett) ** | 1.0 degrees |
±2 degrees C (±0.3%) |
32-1112 degrees F (0-600 degrees C) | |
| CO/CO2 Ratio ** | 0.0001 |
±0.0001 |
0 to 0.9999 | |
| Poison Index ** | 0.01% |
±0.01 |
0 to 99.99 | |
|
** Using dry gases at STP |
||||
Supplied with:
Options:
| SENSOR | RANGE | Resolution | Accuracy | PART# |
| Nitric Oxide - NO1 low range | 0~100ppm | 1ppm |
±2ppm<30ppm ±5ppm>30ppm |
18079 |
| Carbon Monoxide (high range) | 0 to 10% | 0.01% |
±5% from 0.1-10% |
|
| Nitrogen Dioxide NO2 | 0~1,000ppm | 1ppm |
±5ppm<100ppm ±10ppm<500ppm ±5%>500ppm |
10533 |
| Sulfur Dioxide - SO2 low range | 0~100ppm | 1ppm |
±5ppm<100ppm ±5%>100ppm |
18131 |
| Pressure | 0.1 mbar | ±150mbar |
±2% of full scale |