Meters, Test Kits, Inspection Supplies & Tools!

U-Tube Manometer 4.5" Water Column (50018) Red Gage Oil

Model #: 50018

UPC: 00667829500182

Condition: New

Item may vary slightly from image.

$13.50

Ordering more than the quantity shown in stock?
Quantities above the quantity shown in stock will ship on or before 9/1/26 - 9/8/26. Orders ship complete by default — if you would like the in-stock portion shipped separately, please indicate at checkout. Ordering the full quantity in one transaction receives the best pricing and any applicable quantity discounts on the total ordered. Learn more about special orders and split shipments.
Ordered Quantity 1 2-5 6-11 12-23 24+
Price per Unit $13.50 $13.10 $12.69 $12.29 $11.88
Add Qty to Cart:
Product 29 of 32
Category: Manometers

Easy Read Dynameter™ Vacuum Gauge U-Tube Manometer, measures 0 to 4.5 inches of Water Column. Red Gage Oil.

  • Molded scale curved to fit system pipe.
  • Use with Radon Mitigation Systems to measure vacuum between slab and fan.
  • Non-toxic oil filled.
  • Uses a 3/16" hole.
  • Adjustable zero.
  • Molded scale curved to fit system pipe.
  • Compatible with all RadonAway fans except HS series.

Supplied with:

  • Easy Read u-tube manometer.
  • 3/16" x 5" vinyl tubing.
  • (2) self-tap screws.
  • Installation instructions.
  • System and component labels.
  • System information brochure.
  • Clear plastic bag with twist tie for hanging information on system.

Installation Instructions:

  1. Select location on the vertical suction pipe where the vacuum gauge is to be mounted. Pipe surface should be clean and dry.
  2. Remove end caps from both tube ends. Hold gauge upright to prevent loss of gauge fluid (oil).
    • Warning: Do not ingest gage fluid.
    • Caution: Gage fluid can stain.
  3. Remove protective backing from the foam tape on the back of the gauge and firmly press into place on piping.
  4. Allow fluid to settle in gauge for several minutes and then zero the gauge by sliding the tube until the tops of both columns align with the zero mark on the pressure scale.
    The gauge may be fixed in this position using the mounting screws provided.
  5. Drill a 3/16" hole in piping 2" below the gauge.
    • Positioning the hole below the top of the gauge will help prevent condensation from potentially collecting in the U-Tube gauge.
  6. Insert vinyl tube into either opening in gauge tube and push firmly.
  7. Install other end of the vinyl tube into the drilled hole. Apply caulking for airtight connection.
  8. Fill out label using an indelible marker.
  9. Remove label backing and position label next to vacuum gauge ensuring the arrow is lined up with the gauge zero.