Chlorine in Water Test 0-6 ppm Free Chlorine (481026) 50 Tests

Model #: 481026

Condition: New

This item is No Longer Available

No Longer Available
Product 13 of 13
Category: Water Testing
  • Fast accurate results
  • Designed to resist interference from mono-chloramines
  • Free Chlorine test strips combine a wide range of detection with its patented Free Chlorine indicator
  • Ideal for testing in a food processing environment
  • Reagents are impregnated on the test strip pad, and no external chemicals are needed to perform the test

Specifications:

  • Sensitivity: 0, 0.05, 0.1, 0.2, 0.4, 0.6, 0.8, 1.2, 1.5, 2, 2.6, 4, 6 ppm (mg/L)
  • Response time: approximately 40 seconds (see temperature compensation chart)
  • Testing temperature range: 32° to 104° F

Supplied with:

  • 50 test strips
  • Sampling cup
  • Temperature compensation chart
  • Instructions

The test strip is for compliance testing as described in the Federal Register (Vol 72, No. 47, Monday, March 12, 2007, p.11204, ITS Method D99–003). Free Chlorine Water Check can now be treated as an equivalent to other free chlorine test kits. States will have the discretion to approve their use per authority at 40 CFR 141.74 (a) (2). The original recommendation letter (October 2003) from the EPA stated: "We (EPA) believe that the ITS test strips will provide the regulatory community with a valuable option for monitoring free chlorine levels in drinking water."

Municipalities now have a rapid, (40 seconds), accurate, and low–cost option for regulatory compliance monitoring. According to the EPA letter; "The false positive and false negative rates were below 0–1%. Method precision and accuracy were characterized in multiple drinking water matrices at varying chlorine concentrations. For example, the validation studies showed that free chlorine recovery was approximately 100% and relative standard deviation (RSD) was generally below 20% for analysis of drinking water samples fortified with 0.1ppm of free chlorine or above; the chlorination level required by National Primary Drinking Water Regulations is 0.2ppm. Finally, results did not vary across different lots of ITS test strips."

As an alternative to DPD, Free Chlorine Water Check test strips avoid the errors inherent to currently available test methods. The patented design of the strip (US Pat. Nos. 5491094 & 6541369) makes this possible. All of the reagents needed to perform the test are embedded in a "solid state" in the reaction area of the aperture. In comparison to DPD, and according to the manufacturer "the problem with the use of reagent ‘pillows’ is that while the ‘pillow’ itself contains the precise amount of reagent needed to accurately test a defined amount of aqueous solution, the reagent from the open ‘pillow’ can come in contact with the operator’s hands, can be spilled, or can have adulterants or contaminants accidentally added. This creates significant chance for error. If errors in the amount or condition of reagent occurs the test results, and the conclusions reached based on those results, are subject to error. These errors can result in unnecessary, and possibly dangerous, changes in water processing conditions predicated upon false readings. "