RadonAway High Suction Fan Variable Wattage (HS2750) with 4 Speed Settings
RadonAway's HS2750 is an ETL-listed high suction blower designed for professional radon mitigators tackling challenging installations. Multiple speed settings meet site-specific pressures and airflows, easily verified by the built-in magnehelic pressure gauge on the front cover. A new electrical box design with wire terminal strip and two included flexible pipe couplings make for quick, clean site installation.
- 4 blower speed settings (Low, Medium, High, Maximum).
- Built-in 40" magnehelic vacuum gauge confirms system operation.
- Integrated condensate bypass protects motor from moisture.
- Quiet operation; single-stage blower designed for harsh environmental conditions.
- Designed for easy motor replacement.
- Thermally protected — shuts off at 185°F / 85°C; auto-restarts below 75°C.
- Locked rotor protection.
- ETL Listed; conforms to UL STD. 507 and CAN/CSA STD. C22.2 No. 113.
- Not compatible with solid state speed controls.
Specifications
- Voltage: 120 VAC, 60 Hz.
- Maximum current: 4 A.
- Number of speeds: 4.
- Inlet: 3" PVC (3.5" OD).
- Outlet: 2" PVC (2.37" OD).
- Minimum recommended PVC ducting: 3" inlet; 2" outlet.
- Mounting: brackets for vertical mount; (4) 1/4" x 1-1/2" lag screws required (not included).
- Wiring: hard-wire to 120V; all wiring must be performed by a qualified, licensed electrician per NFPA 70.
- Storage temperature range: 32°F – 100°F.
- Thermal cutout: 185°F / 85°C.
NOTE: Do not leave blower installed on system piping without electrical power for more than 48 hours — blower failure may result.
Performance — Typical CFM vs. Static Suction
Speed Setting (Max. Op. Pressure) |
CFM vs. Static Pressure (inches WC) |
Watts @ 120 VAC |
| 2.5" |
5.0" |
7.5" |
10.0" |
12.5" |
15.0" |
20.0" |
25.0" |
| Low (5") |
33 |
24 |
— |
— |
— |
— |
— |
— |
112–123 |
| Medium (10") |
47 |
42 |
34 |
25 |
— |
— |
— |
— |
199–245 |
| High (15") |
— |
— |
47 |
43 |
33 |
23 |
— |
— |
266–337 |
| Maximum (20") |
— |
— |
— |
— |
48 |
43 |
24 |
— |
361–463 |
Shutoff pressure ("WC @ sea level): Low 7.8", Med 13.5", High 17.6", Max 22.6".
*Power consumption varies with actual load conditions. At higher altitudes, reduce operating pressure limits approximately 4% per 1,000 feet.
Dimensions
- 17.5" W x 9.0" D x 18.5" H.
Weight
Accessories Included
- Two flexible pipe couplings.
- Electrical box with 4-speed control switch.
- Mounting brackets.
- Installation & Operating Instructions.
Downloads
HS2750 Installation & Operating Instructions
HS2750 Specifications Sheet